Review




Structured Review

Covidien sils devices
Sils Devices, supplied by Covidien, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sils+devices/sils+device/nct05494086-7-22-24
Average 90 stars, based on 1 article reviews
sils devices - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

other:

Article Title: Initial Experience of Dual-Port Laparoscopic Distal Gastrectomy for Gastric Cancer: A Single-Arm Study.
Article Snippet: Introduction: Dual-port laparoscopic gastrectomy (DPLG) has been widely performed in recent years for treating gastric cancers.. The present study reports our initial experience of dual-port laparoscopic distal gastrectomy (DPLDG).. Methods: From November 2016 to August 2018, 38 consecutive patients underwent DPLDG in our center.

Article Title: Dual-Port Laparoscopic Distal Gastrectomy for Gastric Cancer: A Randomised Clinical Trial
Article Snippet: At present, multi-channel ports that have been reported include Uni-X devices (Pnavel Systems, Brooklyn, NY, USA), TriPort devices (Advanced Surgical Concepts,Wicklow, Ireland), SILS devices (Covidien, Norwalk, CT, USA), OctoPort devices (DalimSurgNet, Seoul, Korea) and self-made multichannel devices from medical centers globally.



Similar Products

90
Covidien sils devices
Sils Devices, supplied by Covidien, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sils+devices/sils+device/nct05494086-7-22-24
Average 90 stars, based on 1 article reviews
sils devices - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

86
Covidien sils port device
A — Photograph showing the location of the incision for the single <t>incision</t> <t>laparoscopic</t> surgery port device, indicated with a red mark [1]. The para-inguinal portals are indicated by green [2] and blue [3] marks. B and C — The surgical model demonstrates a Carmalt forceps grasping the ventral portion of the single incision laparoscopic surgery port [1] for insertion into the abdomen through the incision made at the umbilicus. Views are shown from both a caudal-to-cranial perspective (B) and a lateral perspective (C).
Sils Port Device, supplied by Covidien, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sils+devices/port+sils/pmc12416111-41-8-14
Average 86 stars, based on 1 article reviews
sils port device - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Covidien 2-cm device with multiple working channels sils
A — Photograph showing the location of the incision for the single <t>incision</t> <t>laparoscopic</t> surgery port device, indicated with a red mark [1]. The para-inguinal portals are indicated by green [2] and blue [3] marks. B and C — The surgical model demonstrates a Carmalt forceps grasping the ventral portion of the single incision laparoscopic surgery port [1] for insertion into the abdomen through the incision made at the umbilicus. Views are shown from both a caudal-to-cranial perspective (B) and a lateral perspective (C).
2 Cm Device With Multiple Working Channels Sils, supplied by Covidien, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sils+devices/sils+device/pm40446699-76-2-8
Average 90 stars, based on 1 article reviews
2-cm device with multiple working channels sils - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

96
World Precision Instruments device
A — Photograph showing the location of the incision for the single <t>incision</t> <t>laparoscopic</t> surgery port device, indicated with a red mark [1]. The para-inguinal portals are indicated by green [2] and blue [3] marks. B and C — The surgical model demonstrates a Carmalt forceps grasping the ventral portion of the single incision laparoscopic surgery port [1] for insertion into the abdomen through the incision made at the umbilicus. Views are shown from both a caudal-to-cranial perspective (B) and a lateral perspective (C).
Device, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sils+devices/Low+Toxicity+Silicone+Adhesive/pmc09481124-180-2-9
Average 96 stars, based on 1 article reviews
device - by Bioz Stars, 2026-09
96/100 stars
  Buy from Supplier

90
Frankenman International sil device octo® -port
A — Photograph showing the location of the incision for the single <t>incision</t> <t>laparoscopic</t> surgery port device, indicated with a red mark [1]. The para-inguinal portals are indicated by green [2] and blue [3] marks. B and C — The surgical model demonstrates a Carmalt forceps grasping the ventral portion of the single incision laparoscopic surgery port [1] for insertion into the abdomen through the incision made at the umbilicus. Views are shown from both a caudal-to-cranial perspective (B) and a lateral perspective (C).
Sil Device Octo® Port, supplied by Frankenman International, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sils+devices/sil+device+octo+++port/pm35066629-40-10-18
Average 90 stars, based on 1 article reviews
sil device octo® -port - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Covidien sils-port device
A — Photograph showing the location of the incision for the single <t>incision</t> <t>laparoscopic</t> surgery port device, indicated with a red mark [1]. The para-inguinal portals are indicated by green [2] and blue [3] marks. B and C — The surgical model demonstrates a Carmalt forceps grasping the ventral portion of the single incision laparoscopic surgery port [1] for insertion into the abdomen through the incision made at the umbilicus. Views are shown from both a caudal-to-cranial perspective (B) and a lateral perspective (C).
Sils Port Device, supplied by Covidien, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sils+devices/single+port+device+sils+port/pm31858397-51-38-41
Average 90 stars, based on 1 article reviews
sils-port device - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Covidien port device, the sils port (single incision laparoscopic surgery port)
A — Photograph showing the location of the incision for the single <t>incision</t> <t>laparoscopic</t> surgery port device, indicated with a red mark [1]. The para-inguinal portals are indicated by green [2] and blue [3] marks. B and C — The surgical model demonstrates a Carmalt forceps grasping the ventral portion of the single incision laparoscopic surgery port [1] for insertion into the abdomen through the incision made at the umbilicus. Views are shown from both a caudal-to-cranial perspective (B) and a lateral perspective (C).
Port Device, The Sils Port (Single Incision Laparoscopic Surgery Port), supplied by Covidien, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sils+devices/single+port+device+sils+port/pmc07797361-54-7-0
Average 90 stars, based on 1 article reviews
port device, the sils port (single incision laparoscopic surgery port) - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


A — Photograph showing the location of the incision for the single incision laparoscopic surgery port device, indicated with a red mark [1]. The para-inguinal portals are indicated by green [2] and blue [3] marks. B and C — The surgical model demonstrates a Carmalt forceps grasping the ventral portion of the single incision laparoscopic surgery port [1] for insertion into the abdomen through the incision made at the umbilicus. Views are shown from both a caudal-to-cranial perspective (B) and a lateral perspective (C).

Journal: The Canadian Veterinary Journal

Article Title: Laparoscopic cryptorchidectomy in 10 equids using a single incision laparoscopic surgery (SILS) port device

doi:

Figure Lengend Snippet: A — Photograph showing the location of the incision for the single incision laparoscopic surgery port device, indicated with a red mark [1]. The para-inguinal portals are indicated by green [2] and blue [3] marks. B and C — The surgical model demonstrates a Carmalt forceps grasping the ventral portion of the single incision laparoscopic surgery port [1] for insertion into the abdomen through the incision made at the umbilicus. Views are shown from both a caudal-to-cranial perspective (B) and a lateral perspective (C).

Article Snippet: The peritoneum was penetrated digitally and a lubricated SILS Port device (3 laparoscopic portals; Covidien) was introduced with the aid of Carmalt forceps ( Figure 1 ).

Techniques:

A — Photograph showing a surgical model with a rigid laparoscope (diameter 10 mm, 30°, length 37 cm) inserted through 1 of the 3 channels of the SILS port device [1], along with a vessel-sealing device inserted through the right [2] para-inguinal portal and traumatic grasping forceps inserted through the left [3] para-inguinal portal. B and C — Intraoperative images showing the vessel-sealing device through the right [2] para-inguinal portal transecting the spermatic cord (white arrow) while the traumatic grasping forceps through the left [3] para-inguinal portal hold the right testicle (white asterisk).

Journal: The Canadian Veterinary Journal

Article Title: Laparoscopic cryptorchidectomy in 10 equids using a single incision laparoscopic surgery (SILS) port device

doi:

Figure Lengend Snippet: A — Photograph showing a surgical model with a rigid laparoscope (diameter 10 mm, 30°, length 37 cm) inserted through 1 of the 3 channels of the SILS port device [1], along with a vessel-sealing device inserted through the right [2] para-inguinal portal and traumatic grasping forceps inserted through the left [3] para-inguinal portal. B and C — Intraoperative images showing the vessel-sealing device through the right [2] para-inguinal portal transecting the spermatic cord (white arrow) while the traumatic grasping forceps through the left [3] para-inguinal portal hold the right testicle (white asterisk).

Article Snippet: The peritoneum was penetrated digitally and a lubricated SILS Port device (3 laparoscopic portals; Covidien) was introduced with the aid of Carmalt forceps ( Figure 1 ).

Techniques:

A — Photograph showing a surgical model with a rigid laparoscope (diameter 10 mm, 30°, length 37 cm) [1′] and traumatic grasping forceps [1″] inserted through 1 of the 3 channels of the single incision laparoscopic surgery (SILS) port device [1], along with another set of traumatic grasping forceps inserted through the left [3] para-inguinal portal. B — An intraoperative image showing the traumatic grasping forceps through the left [3] para-inguinal portal transferring the testicle (white asterisk) to the traumatic grasping forceps [1′] inserted through 1 of the 3 channels of the SILS port device. C — An intraoperative image showing the traumatic grasping forceps [1′] inserted through 1 of the 3 channels of the SILS port device as it pulls the testicle (white asterisk).

Journal: The Canadian Veterinary Journal

Article Title: Laparoscopic cryptorchidectomy in 10 equids using a single incision laparoscopic surgery (SILS) port device

doi:

Figure Lengend Snippet: A — Photograph showing a surgical model with a rigid laparoscope (diameter 10 mm, 30°, length 37 cm) [1′] and traumatic grasping forceps [1″] inserted through 1 of the 3 channels of the single incision laparoscopic surgery (SILS) port device [1], along with another set of traumatic grasping forceps inserted through the left [3] para-inguinal portal. B — An intraoperative image showing the traumatic grasping forceps through the left [3] para-inguinal portal transferring the testicle (white asterisk) to the traumatic grasping forceps [1′] inserted through 1 of the 3 channels of the SILS port device. C — An intraoperative image showing the traumatic grasping forceps [1′] inserted through 1 of the 3 channels of the SILS port device as it pulls the testicle (white asterisk).

Article Snippet: The peritoneum was penetrated digitally and a lubricated SILS Port device (3 laparoscopic portals; Covidien) was introduced with the aid of Carmalt forceps ( Figure 1 ).

Techniques: Transferring

The sequence of images illustrates the simultaneous exteriorization of the laparoscope [1′], traumatic grasping forceps [1″], and single incision laparoscopic surgery port device [1] as the intra-abdominal testicle is removed through the umbilical incision, with the right [2] and left [3] para-inguinal portals also visible.

Journal: The Canadian Veterinary Journal

Article Title: Laparoscopic cryptorchidectomy in 10 equids using a single incision laparoscopic surgery (SILS) port device

doi:

Figure Lengend Snippet: The sequence of images illustrates the simultaneous exteriorization of the laparoscope [1′], traumatic grasping forceps [1″], and single incision laparoscopic surgery port device [1] as the intra-abdominal testicle is removed through the umbilical incision, with the right [2] and left [3] para-inguinal portals also visible.

Article Snippet: The peritoneum was penetrated digitally and a lubricated SILS Port device (3 laparoscopic portals; Covidien) was introduced with the aid of Carmalt forceps ( Figure 1 ).

Techniques: Sequencing

The photograph shows a surgical model set up for a unilateral cryptorchid procedure, with a rigid laparoscope (diameter 10 mm, 30°, length 37 cm) [1′] and traumatic grasping forceps [1″] inserted through 1 of the 3 channels of the single incision laparoscopic surgery port device [1]. In addition, Babcock forceps are inserted through the right [2] para-inguinal portal.

Journal: The Canadian Veterinary Journal

Article Title: Laparoscopic cryptorchidectomy in 10 equids using a single incision laparoscopic surgery (SILS) port device

doi:

Figure Lengend Snippet: The photograph shows a surgical model set up for a unilateral cryptorchid procedure, with a rigid laparoscope (diameter 10 mm, 30°, length 37 cm) [1′] and traumatic grasping forceps [1″] inserted through 1 of the 3 channels of the single incision laparoscopic surgery port device [1]. In addition, Babcock forceps are inserted through the right [2] para-inguinal portal.

Article Snippet: The peritoneum was penetrated digitally and a lubricated SILS Port device (3 laparoscopic portals; Covidien) was introduced with the aid of Carmalt forceps ( Figure 1 ).

Techniques: